Comparison of three different lipid removal cleanup techniques prior to the analysis of sulfonamide drug residues in porcine tissues.

Clicks: 387
ID: 63720
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #11 of 66 articles by views in Food science & nutrition

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A number of 17 sulfonamides (SNs) determination in porcine tissues using two new materials including Enhanced Matrix Removal for Lipid (EMR-L) and Oasis PRiME hydrophilic-lipophilic balance (HLB), and the conventional liquid-liquid extraction with n-hexane (LLE) sample preparation methods were evaluated and compared. Samples were extracted uniformly with acidified acetonitrile and cleaned up by the three sample preparation methods, and then, analytes were further separated by ultrahigh-performance liquid chromatography (UHPLC) and detected by a triple quadrupole mass spectrometry (MS/MS) or a quadrupole-time-of-flight tandem mass spectrometry (Q-TOF/MS). The results showed that the matrix effects from the EMR-L and HLB were significantly lower than that from LLE, suggesting that these two new materials are superior to n-hexane in the precipitation of proteins and the adsorption of lipids. Moreover, the recoveries of 17 SNs were quantified by the matrix-matched calibration curve at spiked level of 5, 10, and 20 μg/kg, and 97.0% of the results satisfied method validation requirements. The samples cleaned up by EMR-L and HLB achieved the highest average recovery in liver and kidney with high moisture content, and muscle which is high in fat, respectively. In addition, Q-TOF/MS could play a good role in aided verification based on the result of repeated validation test. In summary, either combination of approaches could be used to achieve monitoring purposes; it is still worthwhile to adopt a specific sample preparation method and MS detector for the quantification in a specific matrix.
Reference Key
wang2019comparisonfood Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wang, Jie;Hu, Qiuhui;Li, Peng;Fang, Yong;Yang, Wenjian;Ma, Ning;Pei, Fei;
Journal Food science & nutrition
Year 2019
DOI
10.1002/fsn3.1158
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.