design and performance analysis of position-based impedance control for an electrohydrostatic actuation system

Klicks: 290
ID: 182658
2018
Kostenloses PDF
Artikelqualität & Leistungskennzahlen
Gesamtqualität
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
KI-Qualitätsbewertung
Nicht analysiert
Readership in this journal
Emerging

Ranked #37 of 90 articles by views in Cancer epidemiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Electrohydrostatic actuator (EHA) is a type of power-by-wire actuator that is widely implemented in the aerospace industry for flight control, landing gears, thrust reversers, thrust vector control, and space robots. This paper presents the development and evaluation of position-based impedance control (PBIC) for an EHA. Impedance control provides the actuator with compliance and facilitates the interaction with the environment. Most impedance control applications utilize electrical or valve-controlled hydraulic actuators, whereas this work realizes impedance control via a compact and efficient EHA. The structures of the EHA and PBIC are firstly introduced. A mathematical model of the actuation system is established, and values of its coefficients are identified by particle swarm optimization. This model facilitates the development of a position controller and the selection of target impedance parameters. A nonlinear proportional-integral position controller is developed for the EHA to achieve the accurate positioning requirement of PBIC. The controller compensates for the adverse effect of stiction, and a position accuracy of 0.08 mm is attained. Various experimental results are presented to verify the applicability of PBIC to the EHA. The compliance of the actuator is demonstrated in an impact test. Keywords: Actuation system, Aerospace, Electrohydrostatic actuator, Force control, Nonlinear dynamics, Particle swarm optimization, Position control
Referenzschlüssel
fu2018chinesedesign Verwenden Sie diesen Schlüssel zum automatischen Zitieren im Manuskript bei Verwendung von SciMatic Manuscript Manager oder Thesis Manager
Autoren
Zeitschrift Cancer epidemiology
Jahr 2018
DOI
DOI nicht gefunden
URL
Schlüsselwörter

Zitationen

Keine Zitationen gefunden. Um eine Zitation hinzuzufügen, kontaktieren Sie den Administrator unter info@scimatic.org

Noch keine Kommentare. Seien Sie der Erste, der diesen Artikel kommentiert.