[Determination of trichlorobenzene in workplace air by solvent desorption gas chromatography].
Clicks: 246
ID: 181761
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
246 views
33 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #13 of 14 articles by views in zhonghua lao dong wei sheng zhi ye bing za zhi = zhonghua laodong weisheng zhiyebing zazhi = chinese journal of industrial hygiene and occupational diseases
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To develop a solvent desorption-gas chromatography method for determination of trichlorobenzene in workplace air. Trichlorobenzene in workplace air were captured by Sampling tube consisting of glass fiber filter and solvent desorption activated carbon and desorbed with carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-electron capture detector. The linear ranges of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 12.20-1220.00, 16.60-1660.00 and 14.80-1480.00 μg/L, respectively, and the related coefficients were between 0.99946 to 0.99948. The relative standard deviations () within the groups of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 1.96%-2.68%, 1.73%-2.82% and 1.81%-2.56%, respectively, and the between the groups were 3.27%-4.25%, 2.85%-4.83% and 3.46%-4.43%, respectively. The average recovery efficiencies were 92.4%, 92.0% and 93.6%, respectively. The minimum quantification concentrations were 0.81, 1.53 and 1.18 μg/m(3), respectively (3 ml desorption solution, 15.00 L sample) . The samples could be stored at room temperature for at least 5 days. This method could be used for monitoring of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene in workplace air.
| Reference Key |
liu2020determinationzhonghua
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, W D;Cai, M S; |
| Journal | zhonghua lao dong wei sheng zhi ye bing za zhi = zhonghua laodong weisheng zhiyebing zazhi = chinese journal of industrial hygiene and occupational diseases |
| Year | 2020 |
| DOI |
10.3760/cma.j.cn121094-20190917-00379
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.