[Determination of trichlorobenzene in workplace air by solvent desorption gas chromatography].

Clicks: 246
ID: 181761
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To develop a solvent desorption-gas chromatography method for determination of trichlorobenzene in workplace air. Trichlorobenzene in workplace air were captured by Sampling tube consisting of glass fiber filter and solvent desorption activated carbon and desorbed with carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-electron capture detector. The linear ranges of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 12.20-1220.00, 16.60-1660.00 and 14.80-1480.00 μg/L, respectively, and the related coefficients were between 0.99946 to 0.99948. The relative standard deviations () within the groups of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 1.96%-2.68%, 1.73%-2.82% and 1.81%-2.56%, respectively, and the between the groups were 3.27%-4.25%, 2.85%-4.83% and 3.46%-4.43%, respectively. The average recovery efficiencies were 92.4%, 92.0% and 93.6%, respectively. The minimum quantification concentrations were 0.81, 1.53 and 1.18 μg/m(3), respectively (3 ml desorption solution, 15.00 L sample) . The samples could be stored at room temperature for at least 5 days. This method could be used for monitoring of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene in workplace air.
Reference Key
liu2020determinationzhonghua Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Liu, W D;Cai, M S;
Journal zhonghua lao dong wei sheng zhi ye bing za zhi = zhonghua laodong weisheng zhiyebing zazhi = chinese journal of industrial hygiene and occupational diseases
Year 2020
DOI
10.3760/cma.j.cn121094-20190917-00379
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.