migração de β-caprolactama de embalagens contendo poliamida 6 para simulante ácido acético 3% e validação do método analítico β-caprolactam migration from polyamide 6 packaging into 3% acetic acid food simulant and validation of the analytical method

Clicks: 319
ID: 165894
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #52 of 124 articles by views in software - practice and experience

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 124 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Este trabalho teve como objetivo desenvolver e validar método analítico para determinar ε-caprolactama no simulante de alimentos solução de ácido acético 3% e estudar sua migração de embalagens contendo poliamida 6 para o simulante em contato. Foi empregada a cromatografia gasosa usando ε-caprolactama como padrão analítico e 2-azociclononanona como padrão interno. A linearidade esteve entre 1,60 e 640,00 µg de ε-caprolactama.mL-1 de simulante, com coeficiente de correlação 0,9999. Os limites de detecção e de quantificação do método foram 0,24 e 1,60 ng, respectivamente. A precisão do método revelou valores de coeficiente de variação menores que 4,3% e a avaliação da exatidão mostrou recuperação de 100 a 106%. O método demonstrou ser eficaz para quantificar ε-caprolactama no simulante, apresentando ampla linearidade, boa precisão e exatidão. No ensaio de migração, embalagens contendo poliamida 6 foram colocadas em tubos de vidro com 10 mL do simulante, que foram hermeticamente fechados e acondicionados a 40 ± 1 °C durante 10 dias. O ensaio de migração foi realizado por imersão total. A quantidade de ε-caprolactama migrada variou de 7,8 a 10,5 e de 6,9 a 7,6 mg.kg-1 de simulante para as embalagens destinadas aos produtos cárneos e queijos, respectivamente. Todas as embalagens atenderam às exigências da Legislação Brasileira para migração de ε-caprolactama.
The aim of this work was to develop and validate an analytical method to determine ε-caprolactam in 3% acetic acid solution and to study its migration from polyamide 6 into food simulant. Gas chromatography was used with ε-caprolactam as an analytical standard and 2-azacyclononanone as an internal standard. The linearity was obtained by the concentration range of 1.60 to 640.00 µg.mL-1, with a correlation coefficient of 0.9999. Detection and quantification limits of the method were 0.24 ng and 1.60 ng, respectively. Relative standard deviations obtained for method precision were less than 4.3%, while method accuracy showed recovery between 100 and 106%. The method was able to quantify ε-caprolactam in the simulant, showing a wide linearity, good precision and accuracy. For the migration assay, polyamide 6 films were placed in glass vials containing 10 mL of simulant, which were hermetically capped and exposed at 40 °C for 10 days (total immersion). The amount of ε-caprolactam that migrated from packaging into the simulant varied from 7.8 to 10.5 and 6.9 to 7.6 mg.Kg-1, for films used as meat products and cheese packaging, respectively.
Reference Key
flix2007foodmigrao Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal software - practice and experience
Year 2007
DOI
10.1590/S0101-20612007000500005
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.