a study of the anechoic performance of rice husk-based, geometrically tapered, hollow absorbers
Clicks: 268
ID: 164439
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
268 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #36 of 304 articles by views in american journal of physiology endocrinology and metabolism
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 304 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Although solid, geometrically tapered microwave absorbers are preferred due to their better performance, they are bulky and must have a thickness on the order of λ or more. The goal of this study was to design lightweight absorbers that can reduce the electromagnetic reflections to less than −10 dB. We used a very simple approach; two waste materials, that is, rice husks and tire dust in powder form, were used to fabricate two independent samples. We measured and used their dielectric properties to determine and compare the propagation constants and quarter-wave thickness. The quarter-wave thickness for the tire dust was 3 mm less than that of the rice husk material, but we preferred the rice-husk material. This preference was based on the fact that our goal was to achieve minimum backward reflections, and the rice-husk material, with its low dielectric constant, high loss factor, large attenuation per unit length, and ease of fabrication, provided a better opportunity to achieve that goal. The performance of the absorbers was found to be better (lower) than −20 dB, and comparison of the results proved that the hollow design with 58% less weight was a good alternative to the use of solid absorbers.
| Reference Key |
iqbal2014internationala
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Muhammad Nadeem Iqbal;Mohd. Fareq Malek;Yeng Seng Lee;Liyana Zahid;Muhammad Shafiq Mezan |
| Journal | american journal of physiology endocrinology and metabolism |
| Year | 2014 |
| DOI |
10.1155/2014/498767
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org