a comparative study of the sintering behavior of pure and manganese-substituted hydroxyapatite

Clicks: 244
ID: 132985
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #251 of 461 articles by views in Nature Materials

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 461 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Hydroxyapatite (HA) is a widely studied biomaterial for its similar chemical composition to bone and its osteoconductive properties. The crystal structure of HA is flexible, allowing for a wide range of substitutions which can alter bioactivity, biodegradation, and mechanical properties of the substituted apatite. The thermal stability of a substituted apatite is an indication of its biodegradation in vivo. In this study, we investigated the thermal stability and mechanical properties of manganese-substituted hydroxyapatite (MnHA) as it is reported that manganese can enhance cell attachment compared to pure HA. Pure HA and MnHA pellets were sintered over the following temperature ranges: 900 to 1300 °C and 700 to 1300 °C respectively. The sintered pellets were characterized via density measurements, mechanical testing, X-ray diffraction, and field emission electron microscopy. It was found that MnHA was less stable than HA decomposing around 800 °C compared to 1200 °C for HA. The flexural strength of MnHA was weaker than HA due to the decomposition of MnHA at a significantly lower temperature of 800 °C compared to 1100 °C for HA. The low thermal stability of MnHA suggests that a faster in vivo dissolution rate compared to pure HA is expected.
Reference Key
zilm2015materialsa Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Michael Zilm;Seamus D. Thomson;Mei Wei
Journal Nature Materials
Year 2015
DOI
10.3390/ma8095308
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.