Determination of bisphenol A in canned food by microwave assisted extraction, molecularly imprinted polymer-solid phase extraction and liquid chromatography-mass spectrometry.
Clicks: 429
ID: 78204
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
429 views
72 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #8 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Bisphenol A (BPA), a known potential endocrine disrupting compound (EDC) is expected to be present in low quantities in canned food due to its migration from the inner surface coating of cans made of epoxy resins. A selective and confirmatory analytical method, based on microwave assisted extraction (MAE), molecularly imprinted solid phase extraction (MISPE) using a polymer prepared by a non-covalent molecular imprinting technique and liquid chromatography coupled with electrospray ionization mass spectrometry (LC-ESI/MS) was developed for the determination of BPA in canned pineapple, tuna and mushrooms. First, the effect of the loading medium of hydro- organic solutions on the binding of BPA and its deuterated analogue on the MISPE sorbent was investigated. Subsequently, the effects of the experimental conditions of the microwave assisted extraction (solvent, sample mass/solvent volume, time and temperature) on the obtained recovery of BPA from canned food were assessed and the parameters were optimized to provide maximum recovery and selectivity. It was demonstrated that the combination of MAE with MISPE permits the use of a selective extraction solvent (methanol/water, 4/6, v/v), simplifying the sample preparation steps and enhancing sample clean-up of complex food matrices. The method was validated in different food matrices, using BPA-d16 as internal standard and quantitative relative recoveries were determined. The precision (RSD %) of the method ranged from 7% to 10% and the limit of detection was at low ng/g level for all food matrices. The determined concentration of BPA in commercial canned samples ranged between 7.3 and 42.3 ng/g.
| Reference Key |
maragou2019determinationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Maragou, Niki C;Thomaidis, Nikolaos S;Theodoridis, Georgios A;Lampi, Eugenia N;Koupparis, Michael A; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2019 |
| DOI |
S1570-0232(19)31478-3
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.