Removal of 17α-ethinylestradiol and caffeine from wastewater by UASB-Fenton coupled system.
Clicks: 350
ID: 99880
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
350 views
35 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 98 articles by views in environmental technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In aquatic systems, some substances considered as endocrine disruptors have been detected, which can be due to their incomplete elimination in wastewater treatment plants (WWTPs) and inadequate disposal of pharmaceuticals. Among these contaminants are 17α-ethinylestradiol (EE2) and caffeine (CAF). Moreover, it has been reported that this kind of contaminants may provoke different adverse effects in many aquatic organisms. Because of that, in the present study, up-flow anaerobic sludge blanket reactors (UASB) coupled with the Fenton process was evaluated for EE2 and CAF removal spiked in wastewater samples. First, the best reaction conditions were established in each process. For UASB reactor, two hydraulic retention times (HRT 8 and 24 h) were evaluated, achieving the highest chemical organic demand (COD) removal (70%) and drug elimination (84-86%) with HRT 24 h. Subsequently, Fenton process was conducted at pH 3 with different levels of Fe (0.05-0.5 mmol/L) and molar ratios Fe:HO (1:1-1:10). Better results were obtained with 0.5 mmol Fe/L, and 1:10 ratio molar Fe:HO. Finally, UASB-Fenton coupled system allowed 80% of COD decrease, almost complete removal of drugs and the toxicity of samples on was reduced from 73 to 30%, demonstrating that this coupled system is a promising and efficient system for pharmaceutical compounds removal from wastewater.
| Reference Key |
lpezvelzquez2020removalenvironmental
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | López-Velázquez, Khirbet;Villanueva-Rodríguez, Minerva;Mejía-González, Gamaliel;Herrera-López, David; |
| Journal | environmental technology |
| Year | 2020 |
| DOI |
10.1080/09593330.2020.1740799
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.