Deconvolution methods for mitigation of transverse blurring in optical coherence tomography.
Clicks: 215
ID: 97942
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
30.0
/100
215 views
27 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #33 of 51 articles by views in ieee transactions on image processing : a publication of the ieee signal processing society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Imaging resolution in optical coherence tomography (OCT) is a key determinant for acquiring clinically useful optical biopsies of tissues. In contrast to light or confocal microscopy, the axial and transverse resolutions in OCT are independent and each can be analyzed individually. A method for mitigating transverse blurring and the apparent loss of transverse resolution in OCT by means of Gaussian beam deconvolution is presented. Such a method provides better representation of a specimen by using known physical parameters of a lens. To implement this method, deconvolution algorithms based on a focal-dependent kernel are investigated. First, the direct inverse problem is investigated using two types of regularization, truncated singular value decomposition, and Tikhonov. Second, an iterative expectation maximization algorithm, the Richardson-Lucy algorithm, with a beam-width-dependent iteration scheme is developed. A dynamically iterative Richardson-Lucy algorithm can reduce transverse blurring by providing an improvement in the transverse point-spread-function for sparse scattering samples in regions up to two times larger than the confocal region of the lens. These deblurring improvements inside and outside of the confocal region, which are validated experimentally, are possible without introducing new optical imaging hardware or acquiring multiple images of the same specimen. Implementation of this method in sparse scattering specimens, such as engineered tissues, has the potential to improve cellular detection and categorization.
| Reference Key |
ralston2005deconvolutionieee
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ralston, Tyler S;Marks, Daniel L;Kamalabadi, Farzad;Boppart, Stephen A; |
| Journal | ieee transactions on image processing : a publication of the ieee signal processing society |
| Year | 2005 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.