Resorbable Versus Titanium Fixation of Le Fort I Osteotomy.
Clicks: 342
ID: 97897
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
71.9
/100
342 views
229 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #13 of 79 articles by views in the journal of craniofacial surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Resorbable and titanium systems have been used in maxillary fixation. The aim of this review was to evaluate stability and morbidity of Le Fort I osteotomy by comparing both systems. It was performed in 11 databases, and reported according to preferred reporting items for systematic reviews and meta-analysis. Randomized and nonrandomized clinical trials, and retrospective comparative studies with patients who underwent nonsegmented Le Fort I osteotomy were included. Eleven articles were selected, with a total of 262 patients treated with resorbable and 252 with titanium fixation. The meta-analysis showed that when measured at point A, horizontal stability was 0.06 mm (95% confidence interval [CI] -0.19, 0.30), vertical stability for impaction was -0.43 mm (95% CI -0.94, 0.07), and for inferior repositioning was -1.29 mm (95% CI -2.62, 0.04). Morbidity was similar in the groups. Regarding infection, resorbable presented an absolute risk (AR) = 0.032, and titanium an AR = 0.025 (P = 1.0). For soft tissue reaction, an AR = 0.120 was shown for resorbable, and an AR = 0.132 for titanium (P = 0.85). Removal of fixation showed an AR = 0.024 for resorbable, and an AR = 0.025 for titanium (P = 1.0). Based on these results, resorbable and metal fixation systems seem to be equivalent with respect to stability and morbidity. This review was limited by the quality of the studies. Future studies should address these quality limitations to improve comparison between these 2 fixation approaches.
| Reference Key |
passeri2020resorbablethe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Passeri, Luis Augusto;Bento, Adriano Mesquita;Vanni, Tazio; |
| Journal | the journal of craniofacial surgery |
| Year | 2020 |
| DOI |
10.1097/SCS.0000000000006248
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org