New sporopollenin-based β-cyclodextrin functionalized magnetic hybrid adsorbent for magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs from water samples.

Clicks: 432
ID: 96943
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 56 articles by views in Royal Society open science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized magnetic β-cyclodextrin functionalized with toluene diisocyanate (TDI) as a linker and further modified with bio-polymeric spores of sporopollenin (MSp-TDI-βCD), was developed for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs), namely, indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP) from water samples prior to their HPLC-DAD determination. The newly synthesized MSp-TDI-βCD was comprehensibly characterized using FT-IR, XRD, SEM-EDX, BET and VSM analyses. The separation of selected NSAIDs on MSp-TDI-βCD from aqueous solution was simply achieved by applying an external magnetic field via a permanent magnet. The MSPE parameters affecting extraction performance, i.e. sorbent dosage, sample volume, extraction and desorption time, type of organic eluent and volume and solution pH were investigated and optimized. The proposed method showed linear range between 0.5 and 500 ng ml, low limit of detection at S/N = 3 (0.16-0.37 ng ml) and limit of quantification at S/N = 10 (0.53-1.22 ng ml). The inter-day ( 15) and intra-day ( 5) precision for the proposed methods given by relative standard deviation (RSD%) was in the range of 2.5-4.0 and 2.1-5.5, respectively. The extraction recoveries of NSAIDs from environmental samples (tap, drinking and river water) ranged from 92.5% to 123.6%, with satisfactory precision (RSD% less than 12.4%).
Reference Key
syed-yaacob2018newroyal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Syed Yaacob, Syed Fariq Fathullah;Kamboh, Muhammad Afzal;Wan Ibrahim, Wan Aini;Mohamad, Sharifah;
Journal Royal Society open science
Year 2018
DOI
10.1098/rsos.171311
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.