Taking the Pressure off the Patient - Understanding Digital Rectal Examinations on a Real Subject.

Clicks: 116
ID: 93736
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #16 of 16 articles by views in ieee transactions on bio-medical engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Better understanding of palpation techniques during unsighted physical examinations has mostly been limited to qualitative and quantitative studies of performance of experts whilst conducting examinations on plastic benchtop models. However, little is known about their performance when conducting such examinations on real subjects.The aim of this paper is to better understand palpation techniques of experts whilst conducting a Digital Rectal Examination on a real subject.We recruited four consultants from relevant specialties and asked them to conduct two DREs on a Rectal Teaching Assistant whilst wearing small position and pressure sensors on their examining finger. We segmented the relevant anatomy from an MRI taken of the pelvic region, registered 3D models and analysed retrospectively performance in relation to executed tasks, supination/pronation, palpation convex hull and pressure applied.Primary care consultants examined the anatomy more holistically compared to secondary care experts, the maximum pressure applied across experiments is 3.3N, overall the pressure applied on the prostate is higher than that applied to rectal walls, and the urologist participant not only applied the highest pressure but also did so with the highest most prominent frequency (15.4 and 25.3 Hz).The results of our research allow for better understanding of experts' technical performance from relevant specialities when conducting a DRE, and suggest the range of pressure applied whilst palpating anatomy.This research will be valuable in improving the design of haptics-based learning tools, as well as in encouraging reflection on palpation styles across different specialities to develop metrics of performance.
Reference Key
granados2020takingieee Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Granados, Alejandro;Cox, Seth;Low-Beer, Naomi;Higham, Jenny;Kneebone, Roger;Bello, Fernando;
Journal ieee transactions on bio-medical engineering
Year 2020
DOI
10.1109/TBME.2020.2971826
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.