Biomechanical properties of optic nerve and retrobulbar structures with 2D and 3D shear wave elastography in patients affected by glaucoma.

Clicks: 398
ID: 93230
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #2 of 29 articles by views in clinical imaging

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study consists of an elastosonography evaluation of both eyes of 40 glaucomatous patients and 40 healthy subjects. We used shear wave elastography with a one-dimensional-array probe to capture two-dimensional images in order to study the optic nerve near the papilla, chorioretinal complex, lateral rectus muscle, and periorbital fat tissue. Furthermore, we used a two-dimensional array probe to capture three-dimensional images to study the optic nerve in toto with multilevel sampling. We obtained qualitative and quantitative data ("absolute" stiffness values). Then, we have investigated these tissue also measuring the "stiffness ratio" values. Statistically significant differences (p < 0.05), between glaucomatous patients and healthy patients, were noted in "absolute" stiffness values in the two-dimensional analysis at the emergence of the optic nerve and chorioretinal complex, and in the three-dimensional analysis at the emergence of the optic nerve (level I°). This result was supported by the statistically significant differences in the "stiffness ratio" values between the optic nerve and the adjacent adipose tissue, obtained both in two- and three-dimensional analyses. Data were subsequently compared with diagnostic tests currently used for glaucoma, which showed a sensitivity of 83% and specificity of 80% relative to those of elastosonography. We propose the use of elastosonography to verify the existence of pathological changes in the mechanical and elastic properties of peri-ocular structures and their variations as a complementary tool in the diagnosis of glaucoma and for follow-up during treatment.
Reference Key
guazzaroni2020biomechanicalclinical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Guazzaroni, Manlio;Ferrari, Donatella;Lamacchia, Feliciana;Salimei, Fabio;Marsico, Salvatore;Citraro, Daniele;Campagnuolo, Tanio;Girardi, Valentina;Orlacchio, Antonio;
Journal clinical imaging
Year 2020
DOI
S0899-7071(20)30028-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.