Instantaneous Phase Coherence Imaging for Near-Field Defects by Ultrasonic Phased Array Inspection.
Clicks: 287
ID: 92360
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
82.3
/100
287 views
211 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #720 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper describes an imaging method for near-field defect detection in aluminum plates based on Green's function recovery and application of instantaneous phase coherence weighting factors. The directly acquired acoustic information of near-field defects is usually obscured by the nonlinear effects due to the physical limitation of the acquisition system. Using the diffuse field to recover the Green's function can effectively retrieve the early time information. However, averaging operations of finite number in this process produces an imperfect imaging result. In order to improve the image quality, two kinds of instantaneous phased coherence weighting factors are used to weight the Green's function to reduce the background noise and improve the signal-to-noise ratio: the instantaneous phase coherence factor (IPCF), and the instantaneous phase weighting factor (IPWF). Experiments are conducted on two aluminum plates with two and four near-field defects, respectively. As a result, the background noise of amplitude images weighted by IPCF and IPWF is less than that of the conventional total focusing method (TFM). In addition, the IPCF image achieves a better signal-to-noise ratio (SNR) than that of IPWF, and the phase discontinuity in an IPWF image is suppressed through the IPCF.
| Reference Key |
zhang2020instantaneoussensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Haiyan;Zeng, Lingtian;Fan, Guopeng;Zhang, Hui;Zhu, Qi;Zhu, Wenfa; |
| Journal | sensors |
| Year | 2020 |
| DOI |
E775
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.