Corrosion Monitoring of Reinforced Steel Embedded in Cement Mortar under Wet-And-Dry Cycles by Electrochemical Impedance Spectroscopy.

Clicks: 355
ID: 88898
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #200 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The primary objective of the present work is to measure the corrosion rate of reinforcing steel embedded in concrete structures in a simulated marine environment of high chloride concentration. The selection of a single frequency that corresponds to the solution resistance and single frequency that corresponds to the charge transfer resistance were performed and measurements were carried out in a relatively faster time. A total of seven cement mortar specimens were prepared. The effect of varying cover thickness (5-50 mm) and rebar distance (10-80 mm) on the electrical resistance of the concrete and corrosion rate of the steel was examined. To simulate the corrosion of reinforced concrete in a marine environment, cement mortars were exposed to 25 wet-dry cycles that involve an immersion for 8 h in 3 wt.% NaCl solution and drying time of 16 h under room temperature. Alternative current (AC) impedance measurements were carried out within a frequency range from 100 kHz to 1 mHz. Results show that the formation of rust layers on rebars has caused a significant decrease in the maximum phase shift to θ = -30°. An accelerated corrosion rate of the rebars was observed during drying stage.
Reference Key
kim2019corrosionsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kim, Je-Kyoung;Kee, Seong-Hoon;Futalan, Cybelle M;Yee, Jurng-Jae;
Journal sensors
Year 2019
DOI
E199
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.