Investigation on the stress response of microbes in acute toxicity assay.
Clicks: 391
ID: 88228
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
391 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #10 of 84 articles by views in analytica chimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Acute toxicity assay by using microbes as bioindicators is an effective tool for reflecting the impact of water pollution on organisms. Until now, the suspended state of microbes is still mainly adopted, because the immobilized state of microbes will cause the poor stability of toxicity assay due to the microbes being reused. Here, an electrochemical biosensor based on biofilm was established for toxicity assay (TOX-biosensor), and the stress response of immobilized microbes in biofilm was demonstrated as the main factor that resulting in instability of the TOX-biosensor, and it can be induced by both of dose and time accumulation. The intensity of stress response for measuring a toxicant absence of organic substance was triple of that presence, indicating extracellular substances can be used for microbial repair and result in the decrease of the consumption of endogenous substance. Herein, a weak magnetic field (WMF) was employed to balance the activity of biofilm in the present TOX-biosensor, and a low intensity of WMF 10 GS was demonstrated to have the function for weakening stress response. Under this condition, the signals of biosensor can be kept stable for a month and the recovery time of dormant TOX-biosensor can be shorted from 50 h to 10 h. Its mechanism may be associated with the special magnetic field inside the organisms and the charge transfer happened in the life activity process.
| Reference Key |
liu2020investigationanalytica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Ling;Zhang, He;He, Jingting;Dong, Shaojun; |
| Journal | analytica chimica acta |
| Year | 2020 |
| DOI |
S0003-2670(19)31393-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.