Strain gauge analysis of implant-supported, screw-retained metal frameworks: Comparison between different manufacturing technologies.
Clicks: 320
ID: 87832
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
320 views
27 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #9 of 9 articles by views in proceedings of the institution of mechanical engineers part h, journal of engineering in medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Over the past decades, the technological development in the medical field, coupled with the ongoing scientific research, has led to the development and improvement of dental prostheses supported by screw-retained metal frameworks. A key point in the manufacture of the framework is the achievement of a passive fit, intended as the capability of an implant-supported reconstruction to transmit minimum strain to implant components as well as to the surrounding bone, when subject to any load. The fitting of four different kinds of screw-retained metal frameworks was tested in this article. They differ both in materials and manufacturing process: two frameworks are made by casting, one framework is made by computer-aided design and computer-aided manufacturing and one framework is made by electric resistance spot welding (WeldONE, DENTSPLY Implants Manufacturing GmbH, Mannheim, Germany). The passivity of the frameworks was evaluated on the entire system, composed of a resin master cast, the implant analogues embedded in the cast and the frameworks. Strains were recorded by means of an electrical strain gauge connected to a control unit for strain gauge measurements. The experimental tests were carried out in the laboratories of the Department of INdustrial engineering at the University of Bologna. The results of the test campaigns, which compared three samples for each technological process, showed that no significant differences exist between the four framework types. In particular, the frameworks made by the resistance welding approach led to a mechanical response that is well comparable to that of the other tested frameworks.
| Reference Key |
degidi2016strainproceedings
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Degidi, Marco;Caligiana, Gianni;Francia, Daniela;Liverani, Alfredo;Olmi, Giorgio;Tornabene, Francesco; |
| Journal | proceedings of the institution of mechanical engineers part h, journal of engineering in medicine |
| Year | 2016 |
| DOI |
10.1177/0954411916653623
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.