Morphological Area Gradient: System-independent Dense Tissue Segmentation in Mammography Images.

Clicks: 407
ID: 83772
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #14 of 127 articles by views in conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 127 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Breast density has been identified as one of the strongest risk factors for breast cancer. However, the development of reliable and reproducible methods for the automatic dense tissue segmentation has been an important challenge. Due to the complexity of the acquisition process of mammography images, current approaches need to be calibrated for specific mammographic systems or require access to raw mammograms. In this work, we introduce the Morphological Area Gradient (MAG) as a generic measure for mammography images. MAG is generic in the sense that it does not need calibration or access to raw mammograms. At the core of MAG is the derivative of the area of segmented tissue with respect to the pixel intensity. We have found that the high-density regions can be automatically segmented by minimizing the MAG of a mammogram. To verify the performance of MAG, we collected 566 full-field digital mammograms using two different medical devices and a human expert manually annotated the high-density regions in each image. The proposed MAG method yields a median absolute error of 7.6% and a Dices similarity coefficient of 0.83, which are superior to other clinically validated state-of-the-art algorithms.
Reference Key
torres2019morphologicalconference Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Torres, German F;Sassi, Antti;Arponen, Otso;Holli-Helenius, Kirsi;Laaperi, Anna-Leena;Rinta-Kiikka, Irina;Kamarainen, Joni;Pertuz, Said;
Journal conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference
Year 2019
DOI
10.1109/EMBC.2019.8857320
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.