Low Complexity CNN Structure for Automatic Bleeding Zone Detection in Wireless Capsule Endoscopy Imaging.

Clicks: 362
ID: 82939
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #25 of 127 articles by views in conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 127 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Wireless capsule endoscopy (WCE) is a swallowable device used for screening different parts of the human digestive system. Automatic WCE image analysis methods reduce the duration of the screening procedure and alleviate the burden of manual screening by medical experts. Recent studies widely employ convolutional neural networks (CNNs) for automatic analysis of WCE images; however, these studies do not consider CNN's structural and computational complexities. In this paper, we address the problem of simplifying the CNN's structure. A low complexity CNN structure for bleeding zone detection is proposed which takes a single patch as input and then outputs a segmented patch of the same size. The proposed network is inspired by the FCN paradigm with a simplified structure. Since it is based on image patches, the resulting network benefits from moderate-sized intermediate feature maps. Moreover, the problem of redundant computations in patch-based methods is circumvented by non-overlapping patch processing. The proposed method is evaluated using the publicly available KID dataset for WCE image analysis. Experimental results show that the proposed network has better accuracy and AUC than previous structures while requiring less computational operations.
Reference Key
hajabdollahi2019lowconference Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Hajabdollahi, Mohsen;Esfandiarpoor, Reza;Najarian, Kayvan;Karimi, Nader;Samavi, Shadrokh;Reza Soroushmehr, S M;
Journal conference proceedings : annual international conference of the ieee engineering in medicine and biology society ieee engineering in medicine and biology society annual conference
Year 2019
DOI
10.1109/EMBC.2019.8857751
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.