Modeling groundwater contaminant transport in the presence of large heterogeneity: A case study comparing MT3D and RWhet.

Clicks: 317
ID: 80860
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #8 of 32 articles by views in hydrogeology journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A case study is presented that implements two numerical models for simulating a 30-year PAT operation conducted at a large contaminated site for which high-resolution data sets are available. A Markov chain based stochastic method is used to conditionally generate the realizations with random distribution of heterogeneity for the Tucson International Airport Area (TIAA) federal Superfund site. The fields were conditioned to data collected for 245 boreholes drilled at the site. Both MT3DMS and the advanced random walk particle method (RWhet) were used to simulate the PAT-based mass removal process. The results show that both MT3DMS and RWhet represent the measured data reasonably, with Root Mean Square Error (RMSE) less than 0.03. The use of fine grids and the total-variation-diminishing method (TVD) limited the effects of numerical dispersion for MT3DMS. However, the effects of numerical dispersion were observed when compared to the simulations produced with RWhet using a larger number of particles, which provided more accurate results with RMSE diminishing from 0.027 to 0.024 to 0.020 for simulations with 1, 20, and 50 particles. The computational time increased with more particles used in the model, but was still much less than the time required for MT3DMS, which is an advantage of RWhet. By showing the results using both methods, this study provides guidance for simulating long-term PAT systems. This work will lead to improve understanding of contaminant transport and plume persistence, and in turn will enhance site characterization and site management for contaminated sites with large plumes.
Reference Key
guo2019modelinghydrogeology Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Guo, Zhilin;Fogg, Graham E;Brusseau, Mark L;LaBolle, Eric M;Lopez, Jose;
Journal hydrogeology journal
Year 2019
DOI
10.1007/s10040-019-01938-9
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.