Development and validation of a high-performance liquid chromatographic method with a fluorescence detector for the analysis of epirubicin in human urine and plasma, and its application in drug monitoring.
Clicks: 264
ID: 80633
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
78.6
/100
264 views
174 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #23 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of the work was to develop a simple, sensitive and accurate liquid chromatography with fluorescence detection (LC-FL) method for the determination of epirubicin in human urine and plasma. Solid phase extraction with HLB cartridges and mixture of dichloromethane:2-propanol:methanol (2:1:1, v/v/v) as the eluent, was used to prepare the samples. The chromatographic analysis was carried out on a Synergi Hydro-RP column with a mobile phase consisting of 40 mM phosphate buffer (pH 4.1) and acetonitrile (69:31, v/v). Epirubicin was monitored at 497 nm and 557 nm for excitation and emission wavelengths, respectively. Validation data confirmed that the limit of detection and limit of quantification was 0.25 ng/mL and 0.5 ng/mL in both matrices. Next, the optimized LC-FL method was applied to determine the level of epirubicin in real samples taken from a 19-year-old patient with metastatic alveolar rhabdomyosarcoma (RMA) to create a drug profile. Plasma and urine samples were collected for 24 h after the end of a 6-hour infusion of epirubicin. The obtained results confirmed that the optimized and validated LC-FL method can be successfully used in drug monitoring therapy, pharmacokinetic and clinical studies. Moreover, the current work is also drawing attention to the relatively high level of epirubicin in the patient urine, which requires compliance with the safety rules in contact with this biological fluid by both medical staff and others, e.g. family members.
| Reference Key |
treder2020developmentjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Treder, Natalia;Maliszewska, Olga;Olędzka, Ilona;Kowalski, Piotr;Miękus, Natalia;Bączek, Tomasz;Bień, Ewa;Krawczyk, Małgorzata Anna;Adamkiewicz-Drożynska, Elżbieta;Plenis, Alina; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2020 |
| DOI |
S1570-0232(19)31292-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.