Radiographical texture analysis improves the prediction of vertebral fracture: an ex vivo biomechanical study.
Clicks: 385
ID: 78710
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
68.4
/100
385 views
250 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #2 of 16 articles by views in Spine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Compression biomechanical tests using fresh cadaveric thoracolumbar motion segments.The purpose of this study was to determine if the combination of bone texture parameters using bone microarchitecture, and bone mineral density (BMD) measurement by dual-energy x-ray absorptiometry provided a better prediction of vertebral fracture than BMD evaluation alone.Bone strength is routinely evaluated using BMD, as measured by dual-energy x-ray absorptiometry. Currently, there is an ongoing debate about the strengths and limitations of bone densitometry in clinical practice. To assess the fracture risk properly, other factors are important to be taken into account such as the macro- and microarchitecture of the bone. Recently, a new high-resolution x-ray device with direct digitization, named bone microarchitecture (BMA, D3A Medical Systems), has been developed to provide a better precision of texture parameters than those previously obtained on digitized films.Twenty-seven 3-level thoracolumbar motion segments (T11, T12, L1, and L2, L3, L4) of excised spines, obtained at the Anatomy Department of Marseille, were studied using bone microarchitecture to estimate 3 textural parameters: fractal parameter Hmean, co-occurrence matrix, and run-length matrix, dual-energy x-ray absorptiometry to measure BMD, and mechanical compression tests to failure. All specimens were examined by computed tomography before and after compression. The prediction of the vertebral failure load was evaluated using multiple regression analyses.Twenty-seven vertebral fractures were observed with a mean failure load of 2636.3 N (standard deviation, 996 N). Fractal parameter Hmean, co-occurrence matrix, and run-length matrix were each significantly correlated with BMD (P< 0.01) and bone strength (P< 0.01). Combining bone texture parameters and BMD significantly improved the fracture load prediction from adjusted r = 0.701 to adjusted r = 0.806 (P< 0.01).In these excised vertebrae, the combination of bone texture parameters with BMD demonstrated a better performance in the failure load prediction than that of BMD alone.N/A.
| Reference Key |
guenoun2013radiographicalspine
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guenoun, Daphne;Le Corroller, Thomas;Acid, Souad;Pithioux, Martine;Pauly, Vanessa;Ariey-Bonnet, Damien;Chabrand, Patrick;Champsaur, Pierre; |
| Journal | Spine |
| Year | 2013 |
| DOI |
10.1097/BRS.0b013e3182a28fa9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.