An Ultrasound-Based Biomedical System for Continuous Cardiopulmonary Monitoring: A Single Sensor for Multiple Information.

Clicks: 266
ID: 75309
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #12 of 16 articles by views in ieee transactions on bio-medical engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Biomedical wearable sensors enable long-term monitoring applications and provide instantaneous diagnostic capabilities. Physiological monitoring can help in both the diagnosis and the ongoing treatment of a vast number of cardiovascular and pulmonary diseases such as hypertension, dysrhythmia, and asthma. In this paper, we present a system capable of monitoring several vital signals and physiological variables that determine the cardiopulmonary activity status. We explore direct measurements of multiple vital parameters with only one sensor and without special constraints. The system employs a PZT-4 piezo transducer stimulated by a suitable analog front end. The system both generates pulsed ultrasound waves at 1 MHz and amplifies reflected echoes to track internal organ motions, mainly that of the heart apex. According to the respiratory motion of the heart, the proposed system provides respiratory and heart cycles information. Promising results were obtained from six subjects with an average accuracy of 96.7% in heartbeats per minute measurement, referenced to a commercial photoplethysmography sensor. It also exhibits 94.5% sensitivity and 94.0% specificity in respiration detection compared to a spirometer signal as a reference.
Reference Key
shahshahani2020anieee Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Shahshahani, Amirhossein;Zilic, Zeljko;Bhadra, Sharmistha;
Journal ieee transactions on bio-medical engineering
Year 2020
DOI
10.1109/TBME.2019.2912407
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.