Using silver nano particles for sampling of toxic mercury vapors from industrial air sample
Clicks: 103
ID: 73292
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
64.5
/100
103 views
81 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #15 of 15 articles by views in journal of health and safety at work
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction: Mercury is one of the toxic metals that damages the nervous system and kidneys. Therefore, monitoring of mercury vapors in the environments is essential.
.Material and Method: A new adsorbent was made from silver nanoparticles on a bed of quartz. The nano-adsorbent was capable for sampling of the trace amounts of mercury vapor from air. In this study, the required mercury vapor was generate by hydride generation atomic absorption spectrometry and the necessary analysis was performed by cold vapor atomic absorption spectrometry. .
Results: Mercury vapors in the Stationary phase, were concentrated as much as 2300 times (Atomic absorption detection limit was 1.15 microgram per liter of air). Thus by this stationary phase, the trace amounts of mercury vapors can be detected up to 0.5 nano gram per liter of air. The detected value of the presented method is 200 times lower than the occupational safety and health administration (OSHA) standards for mercury vapors. Heater accessory at the temperature of 245 °C was used for thermal desorption of mercury from nano silver adsorbent. Optimal time of desorption was obtained 150 seconds and the Repeatability of the method was 58 times. The mercury vapors absorbed on nano silver adsorbent could be maintained at 80 days at the room temperature (25 °C).
.Conclusion: The presented adsorbent is very useful for sampling of the trace amounts of mercury vapors from air. Moreover, it can be regenerated easily is suitable or sampling at 25 to 70 °C. Due to oxidation of silver and reduction in uptake of nanoparticles, oven temperature of 245 °C is used for the recovery of metallic silver. Low amount of adsorbent, high absorbency, high repeatability for sampling, low cost and high accuracy are of the advantages of the presented method.
| Reference Key |
osanloo2014usingjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Osanloo, M. ;Shirkhanloo, H. ;Dadrass, O. Qorban; |
| Journal | journal of health and safety at work |
| Year | 2014 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.