Validation Study and Quality Assurance of Pharmaceutical Water, Waterborne Microorganisms and Endotoxins.
Clicks: 340
ID: 66854
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
76.5
/100
340 views
232 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #5 of 111 articles by views in Biocontrol science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Water for injection (WFI) and purified water are the most widely used and stringently regulated raw material in pharmaceutical manufacturing. WFI is utilized for a parenteral drug product. Water system is monitored at frequent and routine frequency for demonstrating the overall system control and stability of performance. The critical ports demonstrating systemic control should be monitored more frequently. For reducing the overall risk of microbial contamination or microbial build-up, it is important to develop appropriate alert and action levels. The assignment of alert and action levels should be performance-based, derived from the historic data and well below water specifications. These levels and overall excursion rates should be assessed annually. An action level should not be established at a level equivalent to the specification. Consecutive or multiple alert level excursions and each action level excursion should be comprehensively investigated with appropriate corrective and preventive action. It is important to analyze the efficacy of the corrective and preventive action to reduce the overall excursion rates.
| Reference Key |
shintani2016validationbiocontrol
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Shintani, Hideharu; |
| Journal | Biocontrol science |
| Year | 2016 |
| DOI |
10.4265/bio.21.203
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.