A Silicon Resonant Accelerometer Embedded in An Isolation Frame with Stress Relief Anchor.

Clicks: 219
ID: 66511
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #75 of 128 articles by views in micromachines

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 128 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Bias thermal sensitivity is a significant performance parameter of a silicon resonant accelerometer (SRA) and is normally used to evaluate the degree of engineering practicability. Theoretical analysis demonstrates that temperature-induced stress is the dominant factor that determines the bias temperature drift of the custom-designed SRA. To solve this issue, this paper presents an SRA embedded in an isolation frame with stress insensitive anchor that prevents the resonant beams suffering from the thermal stress along the sense axis and thus improving the bias stability. Moreover, a high sensitivity device is achieved by integrating the vibrating beams with the comb fingers without conventional additional mass design. The experimental results show that the nominal resonant frequency of the SRA is around 93 kHz with the sensitivity and nonlinearity of 223.7 Hz/g and 5.1‱. The thermal sensitivities of the two resonant beams are -27.6 ppm/°C and -28.8 ppm/°C, respectively, which can be considered as the results owing to temperature change of the Young's modulus without the thermal stress effect. The bias thermal sensitivity and the stability (1σ) after compensation are tested to be approximately 0.7 mg/°C and 1 mg over the temperature range from -40 °C to 60 °C with ±80 g measurement range.
Reference Key
cui2019amicromachines Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Cui, Jian;Yang, Haibing;Li, Dong;Song, Ziyang;Zhao, Qiancheng;
Journal micromachines
Year 2019
DOI
E571
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.