Biomechanical evaluation of oversized drilling on implant stability - an experimental study in sheep.
Clicks: 220
ID: 62866
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
61.1
/100
220 views
177 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #26 of 67 articles by views in jpma the journal of the pakistan medical association
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To evaluate the effect of oversized drilling on implant success and secondary stability.The experimental study was conducted in Turkey from January to July 2013, after approval by the ethics committee of the University of Ankara, and comprised 2 female sheep. Alumina blasted implants 4mm in diameter and 10mm in length were employed; 16 implant sites were prepared on the proximal tibias of the 2 sheep. In the right tibia, a standard preparation with 3.5mm diameter was performed in the control group, while in the left tibia, an over-preparation with 4.2mm diameter was performed at the experimental group. The implants of the control group were non-mobile, while the experimental group had rotational and vertical movements. The initial implant stability was measured using the resonance frequence analysis. Animals were sacrificed after 12 weeks, and resonance frequence analysis and reverse torque values were measured.In the experimental group, the mean resonance frequence analysis value was 60.25±7.46 (range: 49-74) at the end of the 12-week healing period. There was no statistically significant difference between the two groups (p=0.926). In the removing stage, the mean reverse torque values was 97.75±22.23N/cm (range: 68.63-138.83) for control group and 96.25±21.93N/cm (range: 63.34-126.9) for the experimental group (p=0.84).Osseointegration can be achieved in the absence of primer stability in the 12-week period of healing time even for alumina-blasted implants.
| Reference Key |
yurttutan2016biomechanicaljpma
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yurttutan, Mehmet Emre;Kestane, Recep;Keskin, Ahmet;Dereci, Omur; |
| Journal | jpma the journal of the pakistan medical association |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.