Performance of VITEK mass spectrometry V3.0 for rapid identification of clinical Aspergillus fumigatus in different culture conditions based on ribosomal proteins
Clicks: 295
ID: 6239
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.6
/100
295 views
238 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #687 of 1,693 articles by views in Infection and drug resistance
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,693 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Performance of VITEK mass spectrometry V3.0 for rapid identification of clinical Aspergillus fumigatus in different culture conditions based on ribosomal proteins Longrong Zhou,Yongquan Chen, Yuanhong Xu Department of Clinical Laboratory, The First Affiliated Hospital of Anhui Medical University, Anhui, Hefei, People’s Republic of China Abstract: Fast and accurate discrimination of Aspergillus fumigatus is significant, since misidentification may lead to inappropriate clinical therapy. This study assessed VITEK mass spectrometry (MS) V3.0 for A. fumigatus identification using extracted fungal ribosomal proteins. A total of 52 isolates preliminarily identified as A. fumigatus by traditional morphological methods were inoculated in three different culture media and cultured at two different temperatures. The specific spectral fingerprints of different culture time points (48, 72, 96, and 120 h) were obtained. Of all strains, 88.5% (46/52) were discriminated as A. fumigatus, while the remaining 11.5% (6/52) produced results inconsistent with morphological analysis. Molecular sequencing, as a reference method for species identification, was used to validate the morphological analysis and matrix-assisted laser desorption/ionization time of flight MS. Chi-square tests (Χ2 test, P
| Reference Key |
longrong2017performanceinfection
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Longrong Zhou;Yongquan Chen;Yuanhong Xu and |
| Journal | Infection and drug resistance |
| Year | 2017 |
| DOI |
10.2147/IDR.S148121
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.