Ambulance vehicles as a source of multidrug-resistant infections: a multicenter study in Assiut City, Egypt

Clicks: 242
ID: 6173
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,338 of 1,693 articles by views in Infection and drug resistance

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,693 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Ambulance vehicles as a source of multidrug-resistant infections: a multicenter study in Assiut City, Egypt Mohamed A El-Mokhtar,* Helal F Hetta,* Department of Medical Microbiology and Immunology, Faculty of Medicine, Assiut University, Assiut, Egypt *These authors contributed equally to this work Background: Ambulances may represent a potential source of infection to patients, patients’ relatives, and paramedical staffs. In this study, we analyzed the extent of bacterial contamination in ambulance vehicles and measured the degree of antimicrobial resistance among isolated pathogens. Materials and methods: Twenty-five vehicles were included and 16 sampling points were swabbed in each vehicle. Then the swabs were immediately transferred to the laboratory to identify bacterial contaminants utilizing standard microbiological procedures and API® systems. Antibiotic susceptibility testing and screening for methicillin-resistant staphylococci and extended spectrum β-lactamases (ESBLs)-producing Gram-negative rods were carried out. Results: A total of 400 samples were collected, 589 bacteria were isolated and 286 (48.6%) of the isolates were potentially pathogenic. The highest contamination rate with pathogenic bacteria was detected in suction devices (75.8%) and stethoscopes (67.7%). Staphylococci were the most frequently detected microorganisms (n
Reference Key
mohamed2018ambulanceinfection Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mohamed A El-Mokhtar;Helal F Hetta and
Journal Infection and drug resistance
Year 2018
DOI
10.2147/IDR.S151783
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.