Evaluation of blood culture broths with lysis buffer to directly identify specific pathogens by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry methods
Clicks: 326
ID: 6075
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
70.5
/100
326 views
266 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #379 of 1,693 articles by views in Infection and drug resistance
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,693 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Evaluation of blood culture broths with lysis buffer to directly identify specific pathogens by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry methods Maya Hariu,1,2 Yuji Watanabe,1,2 Nozomi Oikawa,1,2 Takafumi Manaka,1,2 Masafumi Seki1 1Division of Infectious Diseases and Infection Control, Tohoku Medical and Pharmaceutical University Hospital, Sendai City, Miyagi, Japan; 2Department of Laboratory Medicine, Laboratory for Clinical Microbiology, Tohoku Medical and Pharmaceutical University Hospital, Sendai City, Miyagi, Japan Background: Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is now widely used to detect pathogens in clinical settings in Japan. Method: Here, we report the effects of adding lysis buffer in the MALDI-TOF MS method to directly detect bacteria from 3 blood culture systems and compare their detection efficiencies for each pathogen. Results: Blood culture broths from BD, bioMérieux, and Oxoid showed similar detection efficiencies without lysis buffer use and Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa were efficiently detected in all broths when lysis buffer was used. However, Streptococcus pneumoniae was not detected in BD broth when lysis buffer was added. Furthermore, Haemophilus influenzae and Bacteroides fragilis were not detected in all 3 systems when lysis buffer was used. Conclusion: Optimization of blood culture system and lysis buffer is necessary according to each pathogen for direct identification by MALDI-TOF MS methods. Keywords: blood cultures broth, lysis buffer, Escherichia coli, Haemophilus influenzae, Streptococcus pneumoniae, time-of-flight mass spectrometry
| Reference Key |
maya2018evaluationinfection
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Maya Hariu;Yuji Watanabe;Nozomi Oikawa;Takafumi Manaka;Masafumi Seki and |
| Journal | Infection and drug resistance |
| Year | 2018 |
| DOI |
10.2147/IDR.S169197
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.