Distribution and drug resistance of pathogenic bacteria in ventilator-associated pneumonia at a local hospital of North-eastern China

Clicks: 316
ID: 6013
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #446 of 1,693 articles by views in Infection and drug resistance

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,693 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Distribution and drug resistance of pathogenic bacteria in ventilator-associated pneumonia at a local hospital of North-eastern China Yu Wang, Rong Zhang, Wei Liu Department of Emergency, Shengjing Hospital Affiliated to China Medical University, Heping District, Shenyang, Liaoning Province 110004, People’s Republic of China Purpose: To study the distribution of pathogenic bacteria in ventilator-associated pneumonia (VAP), and epidemiological characteristics of extended-spectrum β lactamase (ESBL)-producing bacteria. Patients and methods: Lower respiratory tract secretions from 156 patients with mechanical ventilation were collected using a protective specimen brush (PSB), with quantitative bacterial culture carried out and antibiotic sensitivity measured. ESBLs produced by Gram-negative bacilli were detected using the double disk diffusion method and monitored by plasmid profiles. Results: Gram-negative bacilli accounted for 78.9% of VAP pathogens, with Acinetobacter baumannii (25%), Pseudomonas aeruginosa (19.7%), and Klebsiella pneumoniae (14.5%) as the most common strains. There were 12 Gram-positive strains detected (15.8%); mostly methicillin-resistant. Staphylococcus aureus and methicillin-resistant coagulase-negative Staphylococcus. There were also four strains of Candida albicans detected (5.26%). Most Gram-negative bacilli are sensitive to imipenem, but A. baumannii is serious resistant. ESBLs were detected in nine strains of Gram-negative bacilli; mainly produced by K. pneumoniae and Escherichia coli, to different degrees of multidrug resistance. Five strains of K. pneumoniae-producing ESBLs were from the same clonal origin, as confirmed by plasmid restriction endonuclease analysis. Conclusion: VAP was mainly caused by Gram-negative bacteria, with high antibiotic resistance rates. Plasmids played an important role in the spread of antibiotic resistance among bacteria. Keywords: ventilator-associated pneumonia, pathogenic bacteria, extended-spectrum β lactamases, drug resistance plasmid
Reference Key
yu2018distributioninfection Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Yu Wang;Rong Zhang;Wei Liu and
Journal Infection and drug resistance
Year 2018
DOI
10.2147/IDR.S172598
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.