Design of Ti6Al4V-HA composites produced by hot pressing for biomedical applications
Clicks: 291
ID: 60123
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
77.4
/100
291 views
238 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #35 of 88 articles by views in materials & design
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In order to enhance osteointegration, prostheses surfaces are usually coated with bioactive materials like hydroxyapatite (HA), material found in teeth and bones. Traditional HA coatings were proven adequate for obtaining high-quality coatings on metal substrates. However, due to the implantation process, these coatings can be detached from the metal surface. In this work, a new materials design that aims to avoid this coating detachment scenario is proposed, based on composites of Ti6Al4V alloy reinforced with HA powder, with materials gradation from bulk to surface of the prosthesis, where the titanium bulk provides toughness and the outer regions provide biological performance. In order to assess the mechanical and biological performance of the prosthesis outer region, Ti6Al4V-HA composites with different HA contents were produced and characterized regarding microstructure and mechanical properties. Shear tests were performed and fracture surfaces were analysed. EDS and XRD analysis were performed in order to assess HA possible decomposition due to processing temperature and pressure during the hot pressing route. This work shows that the combination of hot pressing technique and an FGM design approach is a promising solution for manufacturing prosthesis with improved bioactivity that can overcome the detachment problems of solutions based on HA coatings. Keywords: Ti6Al4V, Hydroxyapatite, Hot pressing, Functionally graded material, Composite, Biomedical applications
| Reference Key |
miranda2016designmaterials
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Miranda, G.;Araújo, A.;Bartolomeu, F.;Buciumeanu, M.;Carvalho, O.;Souza, J.C.M.;Silva, F.S.;Henriques, B.; |
| Journal | materials & design |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.