Shortwave Near-Infrared Spectroscopy for Rapid Detection of Aflatoxin B Contamination in Polished Rice.
Clicks: 453
ID: 59961
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.7
/100
453 views
298 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 59 articles by views in Journal of food protection
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The objective of this research was to apply near-infrared spectroscopy, with a short-wavelength range of 950 to 1,650 nm, for the rapid detection of aflatoxin B (AFB) contamination in polished rice samples. Spectra were obtained by reflection mode for 105 rice samples: 90 samples naturally contaminated with AFB and 15 samples artificially contaminated with AFB. Quantitative calibration models to detect AFB were developed using the original and pretreated absorbance spectra in conjunction with partial least squares regression with prediction testing and full cross-validation. The statistical model from the external validation process developed from the treated spectra (standard normal variate and detrending) was most accurate for prediction, with a correlation coefficient () of 0.952, a standard error of prediction of 3.362 μg/kg, and a bias of -0.778 μg/kg. The most predictive models according to full cross-validation were developed from the multiplicative scatter correction pretreated spectra ( = 0.967, root mean square error in cross-validation [RMSECV] = 2.689 μg/kg, bias = 0.015 μg/kg) and standard normal variate pretreated spectra ( = 0.966, RMSECV = 2.691 μg/kg, bias = 0.008 μg/kg). A classification-based partial least squares discriminant analysis model of AFB contamination classified the samples with 90% accuracy. The results indicate that the near-infrared spectroscopy technique is potentially useful for screening polished rice samples for AFB contamination.
| Reference Key |
putthang2019shortwavejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Putthang, R;Sirisomboon, P;Sirisomboon, C Dachoupakan; |
| Journal | Journal of food protection |
| Year | 2019 |
| DOI |
10.4315/0362-028X.JFP-18-318
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.