Aptamer Structure Switch Fluorescence Anisotropy Assay for Small Molecules Using Streptavidin as an Effective Signal Amplifier Based on Proximity Effect.
Clicks: 410
ID: 59959
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
410 views
59 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #10 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fluorescence polarization/anisotropy (FP/FA) approaches are appealing for targets sensing in homogeneous solution due to simplicity, reproducibility and sensitivity. Taking advantage of aptamers, aptamer structure switch FA methods are unique for small molecule detection based on the competition between aptamer-target binding and the hybridization of aptamer and complementary DNA (cDNA). However, usually small FA change is generated in these aptamer assays that only rely on size change caused by hybridization of an oligonucleotide because of the rapid local rotation of fluorophores and small mass change. Here we describe a simple and general aptamer structure switch FA assay for small molecules by employing a large-sized streptavidin (SA) as an effective signal amplifier based on proximity effect to reduce local rotation of fluorophore. In this design, the SA-labeled cDNA hybridizes with fluorescein (FAM)-labeled aptamer, drawing FAM close to SA and bringing a much higher FA value due to restricted local rotation of FAM. Small molecule-aptamer probe binding causes displacement of the SA-labeled cDNA and great decrease of FA. The closeness of SA to FAM in the duplex is key for this proposed strategy to produce large FA changes in target detection. Our method enabled to detect 60 pM aflatoxin B1 (AFB1), 1 nM ochratoxin A (OTA), and 0.5 μM adenosine triphosphate (ATP), respectively. This aptamer FA method combines the merits of aptamers and FA analysis, and it is promising in applications of detection of small molecules with good sensitivity.
| Reference Key |
li2019aptameranalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Yapiao;Zhao, Qiang; |
| Journal | Analytical chemistry |
| Year | 2019 |
| DOI |
10.1021/acs.analchem.9b01253
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.