A naked-eye based strategy for semiquantitative immunochromatographic assay.
Clicks: 291
ID: 59372
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
71.9
/100
291 views
175 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #38 of 84 articles by views in analytica chimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B(1) as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL(-1) and threshold concentrations for TL-I-III were 0.125, 0.5, and 2.0 ng mL(-1), respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0-0.06 ng mL(-1) (negative samples), and 0.06-0.125 ng mL(-1), 0.125-0.5 ng mL(-1), 0.5-2.0 ng mL(-1) and >2.0 ng mL(-1) (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.
| Reference Key |
zhang2012aanalytica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Daohong;Li, Peiwu;Zhang, Qi;Li, Ran;Zhang, Wen;Ding, Xiaoxia;Li, Chang Ming; |
| Journal | analytica chimica acta |
| Year | 2012 |
| DOI |
10.1016/j.aca.2012.06.015
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.