Quantum dot nanobead-based multiplexed immunochromatographic assay for simultaneous detection of aflatoxin B and zearalenone.

Clicks: 390
ID: 59361
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #15 of 84 articles by views in analytica chimica acta

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Immunochromatographic assay (ICA) is a promising technology for on-site detection. Nonetheless, the wide-scale application of ICA is hindered by several disadvantages, such as poor reproducibility, low sensitivity, and single-target detection. Thus, a novel quantum dot nanobead (QB)-based multiplexed ICA (QB-ICA) with multiple test lines was developed in this study for the simultaneous quantitative detection of aflatoxin B (AFB) and zearalenone (ZEN), where QBs with high luminescence were used as labels to enhance the analytical sensitivity of the ICA. Moreover, a streptavidin (SA)-biotin system, which was undisturbed by the target mycotoxins, was introduced as the signal output for the control line. Consequently, stable and reliable T/C values (ratios of signals on the test line to that of the control line) were obtained as quantitative signals. The proposed QB-ICA demonstrated high sensitivity for the simultaneous detection of AFB and ZEN, of which the half-maximal inhibitory concentrations reached as low as 38.98 pg mL and 1.23 ng mL, respectively. At 10% competitive inhibition concentration, the limit detections (LOD) were 1.65 and 59.15 pg mL for AFB and ZEN, respectively. The average recoveries of the intra- and inter-assays ranged from 81.77% to 119.70% and from 94.18% to 111.4% for AFB and ZEN quantification, respectively, and the variation coefficients were less than 12%, thereby indicating that the proposed method is highly accurate and robust. These findings suggest that QB-ICA using SA-biotin system as the signal output of control line is an excellent point-of-care platform for the rapid screening of mycotoxins.
Reference Key
shao2018quantumanalytica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal analytica chimica acta
Year 2018
DOI
S0003-2670(18)30420-3
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.