Minimal astigmatism after sutureless planned extracapsular cataract extraction.

Clicks: 200
ID: 59265
2002
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #16 of 18 articles by views in journal of cataract and refractive surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To evaluate astigmatism after mini-nuc extracapsular cataract extraction (ECCE) in which a chevron incision is enlarged to 6.0 to 7.0 mm for easier nucleus removal and to compare the results with those using a 5.0 mm incision.Department of Ophthalmology, The Edith Wolfson Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Holon, Israel.Thirty eyes of 29 patients were enrolled in this study. Keratometry was performed preoperatively and 3 to 9 months postoperatively. The incision length was 6.0 mm in 6 eyes, 6.5 mm in 10 eyes, and 7.0 mm in 14 eyes that had mature cataract.The mean induced astigmatism calculated by simple subtraction was 0.12 diopter (D) +/- 0.51 (SD), 0.16 +/- 0.98 D, and 0.67 +/- 0.91 D for the 6.0 mm, 6.5 mm, and 7.0 mm incision, respectively. By vector analysis, the mean induced astigmatism was 0.60 +/- 0.30 D, 0.75 +/- 0.67 D, and 1.36 +/- 0.77 D, respectively. Results by both methods showed no significant difference between the previously reported 5.0 mm incision and the 6.0 mm and 6.5 mm incisions. The 7.0 mm group had statistically significantly greater induced astigmatism than the 5.0 mm group (P =.01, simple subtraction; P =.002, vector analysis).Enlarging the size of the chevron incision up to 7.0 mm resulted in a small increase in induced astigmatism. The enlarged incision simplified the operative technique.
Reference Key
burgansky2002minimaljournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Burgansky, Zvia;Isakov, Itzhak;Avizemer, Haggay;Bartov, Elisha;
Journal journal of cataract and refractive surgery
Year 2002
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.