Report of a National Cancer Institute special panel: Characterization of the physical parameters of particle beams for biological research.
Clicks: 243
ID: 57343
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
67.4
/100
233 views
192 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
To define the physical parameters needed to characterize a particle beam in order to allow intercomparison of different experiments performed using different ions at the same facility and using the same ion at different facilities.At the request of the National Cancer Institute (NCI), a special panel was convened to review the current status of the field and to provide suggested metrics for reporting the physical parameters of particle beams to be used for biological research. A set of physical parameters and measurements that should be performed by facilities and understood and reported by researchers supported by NCI to perform pre-clinical radiobiology and medical physics of heavy ions were generated.Standard measures such as radiation delivery technique, beam modifiers used, nominal energy, field size, physical dose and dose rate should all be reported. However, more advanced physical measurements, including detailed characterization of beam quality by microdosimetric spectrum and fragmentation spectra, should also be established and reported. Details regarding how such data should be incorporated into Monte Carlo simulations and the proper reporting of simulation details are also discussed.In order to allow for a clear relation of physical parameters to biological effects, facilities and researchers should establish and report detailed physical characteristics of the irradiation beams utilized including both standard and advanced measures. Biological researchers are encouraged to actively engage facility staff and physicists in the design and conduct of experiments. Modeling individual experimental setups will allow for the reporting of the uncertainties in the measurement or calculation of physical parameters which should be routinely reported.
| Reference Key |
durante2019reportmedical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Durante, Marco;Paganetti, Harald;Pompos, Arnold;Kry, Stephen F;Wu, Xiaodong;Grosshans, David R; |
| Journal | Medical physics |
| Year | 2019 |
| DOI |
10.1002/mp.13324
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.