Blind Source Separation-Based Motion Detector for Imaging Super-Paramagnetic Iron Oxide (SPIO) Particles in Magnetomotive Ultrasound Imaging.

Clicks: 458
ID: 56011
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #3 of 16 articles by views in ieee transactions on medical imaging

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In magnetomotive ultrasound (MMUS) imaging, an oscillating external magnetic field displaces tissue loaded with super-paramagnetic iron oxide (SPIO) particles. The induced motion is on the nanometer scale, which makes its detection and its isolation from background motion challenging. Previously, a frequency and phase locking (FPL) algorithm was used to suppress background motion by subtracting magnetic field off ( -off) from on ( -on) data. Shortcomings to this approach include long tracking ensembles and the requirement for -off data. In this paper, a novel blind source separation-based FPL (BSS-FPL) algorithm is presented for detecting motion using a shorter ensemble length (EL) than FPL and without -off data. MMUS imaging of two phantoms containing an SPIO-laden cubical inclusion and one control phantom was performed using an open-air MMUS system. When background subtraction was used, contrast and contrast to noise ratio (CNR) were, respectively, 1.20±0.20 and 1.56±0.34 times higher in BSS-FPL as compared to FPL-derived images for EL < 3.5 s. However, contrast and CNR were similar for BSS-FPL and FPL for EL ≥ 3.5 s. When only -on data was used, contrast and CNR were 1.94 ± 0.21 and 1.56 ± 0.28 times higher, respectively, in BSS-FPL as compared to FPL-derived images for all ELs. Percent error in the estimated width and height was 39.30% ± 19.98% and 110.37% ± 6.5% for FPL and was 7.30% ± 7.6% and 16.21% ± 10.29% for BSS-FPL algorithm. This paper is an important step toward translating MMUS imaging to in vivo application, where long tracking ensembles would increase acquisition time and -off data may be misaligned with -on due to physiological motion.
Reference Key
hossain2018blindieee Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal ieee transactions on medical imaging
Year 2018
DOI
10.1109/TMI.2018.2848204
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.