Non-Contact Heart Rate Monitoring Using Lab Color Space.

Clicks: 156
ID: 55827
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #143 of 170 articles by views in Studies in health technology and informatics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 170 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Research progressing during the last decade focuses more on non-contact based systems to monitor Heart Rate (HR) which are simple, low-cost and comfortable to use. Most of the non-contact based systems are using RGB videos which is suitable for lab environment. However, it needs to progress considerably before they can be applied in real life applications. As luminance (light) has significance contribution on RGB videos HR monitoring using RGB videos are not efficient enough in real life applications in outdoor environment. This paper presents a HR monitoring method using Lab color facial video captured by a webcam of a laptop computer. Lab color space is device independent and HR can be extracted through facial skin color variation caused by blood circulation considering variable environmental light. Here, three different signal processing methods i.e., Fast Fourier Transform (FFT), Independent Component Analysis (ICA) and Principal Component Analysis (PCA) have been applied on the color channels in video recordings and blood volume pulse (BVP) has been extracted from the facial regions. In this study, HR is subsequently quantified and compare with a reference measurement. The result shows that high degrees of accuracy have been achieved compared to the reference measurements. Thus, this technology has significant potential for advancing personal health care, telemedicine and many real life applications such as driver monitoring.
Reference Key
rahman2016noncontactstudies Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Rahman, Hamidur;Ahmed, Mobyen Uddin;Begum, Shahina;
Journal Studies in health technology and informatics
Year 2016
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.