On-Orbit Signal-to-Noise Ratio Test Method for Night-Light Camera in Luojia 1-01 Satellite Based on Time-Sequence Imagery.

Clicks: 336
ID: 55437
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #615 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Night-light remote sensing imaging technologies have increasingly attracted attention with the development and application of focal plane arrays. On-orbit signal-to-noise ratio (SNR) test is an important link to evaluate night-light camera's radiometric performance and the premise for quantitative application of remote sensing imageries. Under night-light illumination conditions, the illuminance of ground objects is very low and varies dramatically, the spatial uniformity of each pixel's output cannot be guaranteed, and thus the traditional on-orbit test methods represented by variance method are unsuitable for low-resolution night-light cameras. To solve this problem, we proposed an effective on-orbit SNR test method based on consecutive time-sequence images that including the same objects. We analyzed the radiative transfer process between night-light camera and objects, and established a theoretical SNR model based on analysis of the generation and main sources of signal electrons and noise electrons. Finally, we took Luojia 1-01 satellite, the world's first professional night-light remote sensing satellite, as reference and calculated the theoretical SNR and actual on-orbit SNR using consecutive images captured by Luojia 1-01 satellite. The actual results show the similar characteristics as theoretical results, and are higher than the theoretical results within the reasonable error tolerance, which fully guarantee the detection ability of night-light camera and verify the validity of this time-sequence-based method.
Reference Key
wang2019onorbitsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal sensors
Year 2019
DOI
E4077
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.