Novel Technique and Step-by-Step Construction of a Computer-Guided Stent for Mandibular Distraction Osteogenesis.
Clicks: 330
ID: 53540
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
70.6
/100
330 views
209 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 79 articles by views in the journal of craniofacial surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Distraction osteogenesis is an integral part in management of mandibular defects associated with hemifacial microsomia and post-ankylotic mandibular defects. The most difficult part in distraction osteogenesis is the prediction of distraction vector and risk of injury to vital structures as inferior alveolar. The present study aimed to present 3-dimensionally constructed computer-guided splints in distraction osteogenesis to get an ideal vector and minimal risk of vital structures injury.The technical note presents cases series of 6 patients who had computer-guided distraction osteogenesis surgery using prefabricated splints.The distance between the virtual and physical pins and osteotomy was measured, and the deviation of the vector angle and osteotomy angle was also assessed. Average deviation in pin distance was 3 mm and in vector angle 13.5°. Average deviation in osteotomy distance was 2.6 mm and in osteotomy angle 14.4°. None of the cases had injury to vital structure. There was significant improvement (P = 0.0078) in the medial canthus-buccal commissure distance where the arithmetic mean improved from 59.6 (SD = 10.1) mm pre-distraction in the defective side to 67.1 (SD = 8) mm post-distraction. The degree of correction was 97% compared to the normal side.3D printed surgical stents were successful in transferring the virtual treatment plan of mandibular distraction osteogenesis into the surgical theatre with an acceptable margin of error and without injury to any vital structures.
| Reference Key |
hany2019novelthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hany, Hossam El-Dien;El Hadidi, Yasser Nabil;Sleem, Heba;Taha, Moustafa;El Kassaby, Marwa; |
| Journal | the journal of craniofacial surgery |
| Year | 2019 |
| DOI |
10.1097/SCS.0000000000005614
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.