Heuristic evaluation and simulated use testing of infusion pumps to inform pump selection.
Clicks: 272
ID: 53318
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
73.4
/100
272 views
184 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #46 of 71 articles by views in International journal of medical informatics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Poorly designed infusion pumps can lead to user errors and adverse incidents. Therefore, assessments of their usability and performance that can inform managerial decisions about the selection of appropriate medical devices are essential.This study aimed to identify design deficiencies and evaluate the usability and performance of four infusion pump models and thus inform decisions about infusion pump selection.Four evaluators evaluated the interface designs of the pumps according to a series of design principles in a heuristic evaluation in order to identify pump design deficiencies. Additionally, 60 registered nurses participated in simulated use testing to perform a series of tasks using the pumps in order to examine the pump performances. Outcome measures included task completion time, frequency of deviations, frequency of requests for assistance, and nurses' perceptions.Design issues identified included system status visibility, information access, and error prevention. The results of simulated use testing favored some pumps over others, depending on which outcome measures were considered.Heuristic evaluations and simulated use testing can provide information about the basic usability of medical devices and related operational issues. However, practitioners should select appropriate evaluation principles, testing tasks, and outcome measures based on the tested medical devices and contexts.
| Reference Key |
liu2019heuristicinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Kaifeng;Chan, Foon-Yee;Or, Calvin Kalun;Sun, David Tin-Fung;Lai, Wai-See;So, Hing-Yu; |
| Journal | International journal of medical informatics |
| Year | 2019 |
| DOI |
S1386-5056(19)30062-0
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.