Simultaneous determination of shanzhiside methyl ester, 8-O-acetylshan- zhiside methyl ester and luteolin-7-O-β-D-glucopyranoside in rat plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study after oral administration of Lamiophlomis rotata Pill.
Clicks: 377
ID: 53310
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
79.9
/100
377 views
236 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #12 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A rapid, sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the quantification of shanzhiside methyl ester, 8-O-acetylshanzhiside methyl ester and luteolin-7-O-β-D-glucopyranoside of Lamiophlomis rotata Pill in rat plasma was developed and validated. After liquid-liquid extraction with n-butyl alcohol/ethyl acetate (70:30, v/v), analytes and paeoniflorin (internal standard, IS) were separated on an Acquity BEH UPLC C18 column (100 × 2.1 mm, 1.7 μm) with gradient elution at a flow rate of 0.2 mL/min. All calibration curves had good linearity (r>0.9929) over the concentration ranges of 1-1000 ng/mL for shanzhiside methyl ester and 8-O-acetylshanzhiside methyl ester, 0.3-150 ng/mL for luteolin-7-O-β-D-glucopyranoside. The intra- and inter-day precisions were all within 11.1% and the accuracy (relative error, RE%) all ranged from -13.6% to 5.3%. The method also guaranteed an acceptable selectivity, recovery and stability, which was successfully applied to a pharmacokinetic study of the three analytes in rats after oral administration of Lamiophlomis rotata Pill.
| Reference Key |
chen2016simultaneousjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Chen, Jing;Wang, Yang;Liang, Xinlei;Sun, Tingting;Luo, Jinghan;Guo, Xingjie;Zhao, Longshan; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2016 |
| DOI |
10.1016/j.jchromb.2016.03.021
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.