Use of pulsed electron avalanche knife (PEAK) PlasmaBlade™ in patients undergoing implantation of subcutaneous implantable cardioverter-defibrillator.
Clicks: 327
ID: 5066
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Star Article
84.3
/100
322 views
261 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Surgical implantation of subcutaneous implantable cardioverter-defibrillators (S-ICD) requires preparation of a deeper and larger pocket. Infection and bleeding complications are reported, particularly in patients requiring antiplatelet therapy (APT) or being on oral anticoagulation (OAC), with rates up to 25%. The pulsed electron avalanche knife (PEAK) PlasmaBlade™ has been reported to reduce bleeding complications. The purpose of this study was to evaluate the safety and feasibility of a PEAK guided S-ICD implantation with respect to perioperative complications.We enrolled 36 consecutive patients (75% male; mean age 52.1 ± 14.4 years) undergoing S-ICD implantation. Periprocedural safety endpoints comprised major complications including pocket hematomas, wound infections, bleeding (BARC ≥2) or events requiring interventions. Patients were divided into three groups according to management of their anticoagulation: i.) APT, n = 15 (41.7%); ii.) OAC, n = 10 patients (27.8%); iii.) none (neither OAC nor APT), n = 11 (30.6%). Mean procedure duration was 33.1 ± 13.4 min. Mean length of hospital stay was 3.3 ± 2.1 days. Overall analysis showed no differences between the 3 groups with respect to major complications, major bleeding episodes or other procedural parameters, beside a trend towards more minor hematomas in the OAC group (OAC: 22.2% vs. APT: 11.4% vs. none: 9.1%; = 0.15).The results of our pilot study suggest that intermuscular S-ICD implantation using PEAK is safe and potentially beneficial in patients receiving OAC or APT with respect to prevention of bleeding complications. These results support the rationale for large prospective controlled trials evaluating a beneficial effect of PEAK use in S-ICD implantation procedures.
| Reference Key |
kaya2019useinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kaya, Elif;Siebermair, Johannes;Azizy, Obayda;Dobrev, Dobromir;Rassaf, Tienush;Wakili, Reza; |
| Journal | international journal of cardiology heart & vasculature |
| Year | 2019 |
| DOI |
10.1016/j.ijcha.2019.100390
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.