A Palm-Sized Cryoprobe System with a Built-in Thermocouple and Its Application in an Animal Model of Epilepsy.
Clicks: 338
ID: 49045
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
80.0
/100
338 views
235 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #8 of 16 articles by views in ieee transactions on bio-medical engineering
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The purpose of this study is to propose a palm-sized cryoprobe system with a built-in thermocouple (TC) for highly accurate and sensitive temperature measurements and to verify the effectiveness of the system.Conventional cryoprobe systems based on the boiling effect of a refrigerant have triple coaxial tubes. In the proposed system, the outer and middle coaxial tubes are made of two different metals that are welded only at the probe tip, thereby forming a TC. The thermoelectric properties of the built-in TC and measurement accuracy were investigated in agar in a constant-temperature chamber. The system was also applied in a penicillin G-induced rat brain epilepsy model.We verified that the built-in TC has appropriate thermoelectric properties and that the system more accurately and sensitively measured transient temperature changes at the probe tip wall compared to conventional systems, showing the cooling performance of the system. In the rat model, epileptiform activities disappeared on freezing and reliable cell necrosis was achieved at an end temperature of -45.2 ± 1.6 °C.The proposed system is suitable for reliable cryosurgery.The system is probably to be valuable for clarifying the relationship between freezing temperature and cell necrosis in vivo.
| Reference Key |
tokiwa2019aieee
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tokiwa, Tatsuji;Zimin, Lev;Ishiguro, Hiroshi;Inoue, Takao;Kajigaya, Hiroshi;Nomura, Sadahiro;Suzuki, Michiyasu;Yamakawa, Takeshi; |
| Journal | ieee transactions on bio-medical engineering |
| Year | 2019 |
| DOI |
10.1109/TBME.2019.2901530
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.