Simultaneous analysis of PAHs and BTEX in soil by a needle trap device coupled with GC-FID and using response surface methodology involving Box-Behnken design.

Clicks: 338
ID: 48803
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #18 of 84 articles by views in analytica chimica acta

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Polyaniline silica (Silica/PANI) organic-inorganic nanocomposite was synthesized by combining electrospinning and in-situ polymerization processes. This strategy prevented the aggregation of PANI during the polymerization and led to higher synthesis's yield and more uniformity of the produced composite. The structure and morphology of the nanocomposite was characterized using Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and X-ray diffraction (XRD) techniques. The prepared nanocomposite was then packed inside a stain-steel needle and evaluated as a needle trap device (NTD), for simultaneous headspace extraction of polycyclic aromatic hydrocarbons (PAHs) and benzene, toluene, ethylbenzene, and xylenes (BTEX) in polluted soil samples, before GC-FID analysis, as a low-cost and robust detector. Response surface methodology (RSM) involving Box-Behnken design (BBD) was implemented to evaluate the effective experimental variables and subsequent introduction of a multiple function to describe the experimental conditions for the extraction of the analytes. Wide calibration plots (1-2000 ng g for BTEX and 0.2-2000 ng g for PAHs) with acceptable linearity (R > 0.99) were obtained under the optimal conditions. The limits of detection were found to be 0.02-0.1 ng gfor BTEX and 0.001-0.01 ng g for PAHs. The calculated standard deviations were 7.3-13.2% (n = 6). The developed NTD-GC-FID method was successfully applied for the extraction and determination of PAHs and BTEX in contaminated soil samples.
Reference Key
dalvand2019simultaneousanalytica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Dalvand, Kolsoum;Ghiasvand, Alireza;
Journal analytica chimica acta
Year 2019
DOI
S0003-2670(19)30901-8
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.