Fourier Transform Spectrometry with Fourier Analysis of the Interferogram as Just an Optional Tool.

Clicks: 329
ID: 48601
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #97 of 475 articles by views in ACS omega

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 475 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Fourier transform spectrometers replace the traditional dispersive frequency analyzer by a Michelson interferometer. The spectrum is the Fourier transform of the interferogram constituting the raw output. The method is a primary tool for chemical analysis because it has decisive advantages over the dispersive one for analyzing infrared electromagnetic radiation (Fourier transform infrared, FTIR). A new procedure for dealing with the raw interferometric output of the instrument, not needing Fourier transformation and having additional advantages, is put forward here. It rests on recent advances in the theory of the interaction of matter with electromagnetic radiation yielding first principles analytic expressions for the Fourier transform of the spectral lineshapes, which can be fitted directly to the experimentally measured interferogram. The relevant physical information, as the integrated intensities of the electronic transitions and their net energy release, not affected by Stokes shifts, is readily obtained in the fitting procedure. Ulterior analysis of the spectra, introducing phenomenological standard interpolation functions to deconvolute and integrate peaks, becomes unnecessary. Both methods, standard FTIR and the one outlined here, demand little computer time and can be used simultaneously with synergistic effects.
Reference Key
lagos2018fourieracs Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Lagos, Miguel;Paredes, Rodrigo;Retamal, César;
Journal ACS omega
Year 2018
DOI
10.1021/acsomega.8b02914
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.