Simultaneous determination of a ternary mixture of doxylamine succinate, pyridoxine hydrochloride, and folic acid by the ratio spectra-zero-crossing, double divisor-ratio spectra derivative, and column high-performance liquid chromatographic methods.
Clicks: 392
ID: 45992
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
63.5
/100
392 views
254 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #10 of 363 articles by views in journal of aoac international
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 363 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Three simple, rapid, and accurate methods, i.e., the derivative ratio spectra-zero-crossing method (method I), double divisor-ratio spectra derivative method (method II), and column reversed-phase high-performance liquid chromatographic (RP-HPLC) method (method III) were developed for the simultaneous determination of doxylamine succinate (DOX), pyridoxine hydrochloride (PYR), and folic acid (FA) in their ternary mixtures and in tablets. In methods I and II, the calibration graphs were linear in the range of 2.5-80, 1.0-40, and 1.0-30 microg/mL for DOX, PYR, and FA, respectively. In the HPLC method, the separation of these compounds was performed using mobile phase consisting of 0.05 M phosphate buffer (pH 6.3)-methanol-acetonitrile (50 + 20 + 30, v/v/v), and UV detection was performed at 263 nm. Linearity was observed between the concentrations of the analytes and peak areas [correlation coefficient (r) > or =0.9998] in the concentration range of 1.0-200, 4.0-600, and 4.0-600 microg/mL for DOX, PYR, and FA, respectively. The standard deviation of retention time in method III was 0.011, 0.015, and 0.016 for DOX, PYR, and FA, respectively. The precision studies for all of the methods gave relative standard deviation values of <2%. The results obtained from the methods were statistically compared by means of Student's t-test and the variance ratio F-test. It was concluded that all of the developed methods were equally accurate, sensitive, and precise. These methods could be applied to determine DOX, PYR, and FA in their combined dosage forms.
| Reference Key |
pathaksimultaneousjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Pathak, Ashutosh;Rajput, Sadhana J; |
| Journal | journal of aoac international |
| Year | Year not found |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.