Comparison of two beam angular optimization algorithms guided by automated multicriterial IMRT.
Clicks: 378
ID: 45271
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
68.8
/100
378 views
261 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #8 of 25 articles by views in Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To compare two beam angle optimization (BAO) algorithms for coplanar and non-coplanar geometries in a multicriterial optimization framework.40 nasopharynx patients were selected for this retrospective planning study. IMRT optimized plans were produced by Erasmus-iCycle multicriterial optimization platform. Two different algorithms, based on a discrete and on a continuous exploration of the space search, algorithm i and B respectively, were used to address BAO. Plan quality evaluation and comparison were performed with SPIDERplan. Statistically significant differences between the plans were also assessed.For plans using only coplanar incidences, the optimized beam distribution with algorithm i is more asymmetric than with algorithm B. For non-coplanar beam optimization, larger deviations from coplanarity were obtained with algorithm i than with algorithm B. Globally, both algorithms presented near equivalent plan quality scores, with algorithm B presenting a marginally better performance than algorithm i.Almost all plans presented high quality, profiting from multicriterial and beam angular optimization. Although there were not significant differences when average results over the entire sample were considered, a case-by-case analysis revealed important differences for some patients.
| Reference Key |
ventura2019comparisonphysica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ventura, Tiago;Rocha, Humberto;da Costa Ferreira, Brigida;Dias, Joana;Lopes, Maria do Carmo; |
| Journal | Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) |
| Year | 2019 |